Performance/design and product configuration requirements power distribution unit (PDU) for data subsystem Array E Apollo Lunar Surface Experiments Package system
Performance/design and product configuration requirements power distribution unit (PDU) for data subsystem Array E Apollo Lunar Surface Experiments Package system
dc.contributor.author | Steinmeyer, D. J. (Don J.) | |
dc.date.accessioned | 2017-08-09T14:44:37Z | |
dc.date.available | 2017-08-09T14:44:37Z | |
dc.date.issued | 1971 | |
dc.description.abstract | his specification establishes the requirements for performance, design, test, and qualification of the component identified ast he power distribution unit (PDU) of the central station subsystem (specification AL 210 100) for the Apollo Lunar Surface Experiments Package (ALSEP) Array E. | |
dc.description.statementofresponsibility | prepared by D. J. Steinmeyer. | |
dc.format.extent | 31 leaves | |
dc.format.mimetype | application/pdf | |
dc.identifier.other | 31111000675817 | |
dc.identifier.uri | https://hdl.handle.net/20.500.11753/871 | |
dc.language.iso | en | |
dc.publisher | Bendix Aerospace Systems Division. | |
dc.subject.lcc | TL789.8.U6A5 | |
dc.subject.lcsh | Power electronics | |
dc.subject.lcsh | Apollo Lunar Surface Experiments Package | |
dc.title | Performance/design and product configuration requirements power distribution unit (PDU) for data subsystem Array E Apollo Lunar Surface Experiments Package system | |
dc.title.alternative | Power distribution unit (Array E) |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- 31111000675817.pdf
- Size:
- 1.29 MB
- Format:
- Adobe Portable Document Format
- Description: