Investigation into the scrambling of Array E Qualification Model PDU relays at turn-on
Investigation into the scrambling of Array E Qualification Model PDU relays at turn-on
No Thumbnail Available
Date
1972
Authors
Thomas, D. J.
Journal Title
Journal ISSN
Volume Title
Publisher
Bendix Aerospace Systems Division
Abstract
During the C/S Functional Test (TP2365551) on the Array E Qualification Model, it was determined that the initial position of Power Distribution Unit (PDU) relays following a slow turn-on resulted in a scrambled status. This discrepancy was documented in DR AC4186 and FR E6. This report documents the analysis and design change to be incorporated in the PDU to eliminate this discrepant operation,