dc.description.abstract |
The purpose of this EATM is to answer the questions raised at the PSEP CDR regarding cutting the unused experiment cables. It is shown that there will be no impact on system performance as a result of cutting/these unused cables. |
|
dc.description.statementofresponsibility |
prepared by H. Wilson. |
|
dc.format.extent |
4 leaves |
|
dc.format.mimetype |
application/pdf |
|
dc.language.iso |
en |
|
dc.publisher |
Bendix Aerospace Systems Division |
|
dc.relation.ispartofseries |
EATM |
|
dc.source.uri |
https://www.lpi.usra.edu/lunar/ALSEP/pdf/31111000672681.pdf |
|
dc.subject.lcc |
TL789.8.U6A5 |
|
dc.subject.lcsh |
Early Apollo Scientific Experiments Package |
|
dc.subject.lcsh |
Seismology--Instruments |
|
dc.title |
Impact of open lines in experiment cables |
|