USRA Houston Repository

Investigation of Flight II Central Station overvoltage condition

Show simple item record

dc.contributor.author Mansour, John.
dc.date.accessioned 2015-09-09T22:27:13Z
dc.date.available 2015-09-09T22:27:13Z
dc.date.issued 1968
dc.identifier.other 31111000666873
dc.identifier.uri https://hdl.handle.net/20.500.11753/203
dc.description.abstract The purpose of this ATM is to document the results of the Reliability/Engineering investigation of the overvoltage condition that occurred while performing the Flight II Central Station power dissipation test. The objective was to assess the flight worthiness of the C/S components and to identify any overstressed piece parts.
dc.description.statementofresponsibility prepared by J. Mansour.
dc.format.extent 14 leaves
dc.format.mimetype application/pdf
dc.language.iso en
dc.publisher Bendix Aerospace Systems Division
dc.relation.ispartofseries ALSEP technical memorandum
dc.source.uri https://www.lpi.usra.edu/lunar/ALSEP/pdf/ALSEP%20%23289%20-%20Invest_Flight%20II%20CS%20Overvoltage%20Condition_ATM%20800.pdf
dc.subject.lcc TL789.8.U6A5
dc.subject.lcsh Apollo Lunar Surface Experiments Package
dc.subject.lcsh Overvoltage
dc.title Investigation of Flight II Central Station overvoltage condition