ALSEP prototype "A" Central Station final thermal analysis and test results

Show simple item record

dc.contributor.author Johnson, P. A., 1938-
dc.date.accessioned 2015-09-09T22:27:11Z
dc.date.available 2015-09-09T22:27:11Z
dc.date.issued 1968
dc.identifier.other 31111000666717
dc.identifier.uri https://hdl.handle.net/20.500.11753/190
dc.description.abstract This ATM presents the final thermal analysis and test data on the ALSEP Prototype "A" Central Station, with the primary purpose of improving the Central Station analytical model for use in future pretest and flight steady-state temperature predictions in a simulated or real environment.
dc.description.statementofresponsibility prepared by P. A. Johnson.
dc.description.tableofcontents Introduction -- Objectives -- Summary of Results and Conclusions -- Thermal Model -- Analysis Methods -- Conduction -- Heat Inputs -- Heat Leak Through External Cables -- Discussion
dc.format.extent x, 165 leaves
dc.format.mimetype application/pdf
dc.language.iso en
dc.publisher Bendix Aerospace Systems Division
dc.relation.ispartofseries ALSEP technical memorandum
dc.source.uri https://www.lpi.usra.edu/lunar/ALSEP/pdf/ALSEP%20%23279%20-%20Proto%20A%20CS_Therm%20Analy_Tests_Final_ATM%20796.pdf
dc.subject.lcc TL789.8.U6A5
dc.subject.lcsh Apollo Lunar Surface Experiments Package
dc.subject.lcsh Electronics--Materials--Effect of temperature on
dc.title ALSEP prototype "A" Central Station final thermal analysis and test results
dc.title.alternative Apollo Lunar Surface Experiments Package prototype "A" Central Station final thermal analysis and test results